详细参数 | |||
---|---|---|---|
品牌 | 其他 | 型号 | 其他 |
35
Mechanical contact: SPDT gold flashed. Power switch: 3A per 24Vdc – 2Aper 240Vac (resistance load)
Mechanical life cycle: about 100 million operations
Electrical life cycle: over 1,5 million operations at max. load
Operating ambient temperature: from -40°C (-50°C)2 to +105°C - (resin sealed model)
35H
Mechanical contact: SPDT gold flashed. Power switch: 3A per 24Vdc – 2A per 240Vac (resistance load)
Mechanical life cycle: about 100 million operations
Electrical life cycle: over 1,5 million operations at max. load
Operating ambient temperature: from -40°C (-50°C)2 to +105°C - (hermetically sealed model)
7H
Mechanical contact: DPDT palladium silver. Power switch: from 1A per 24Vdc – 2A per 240Vac (resistance load)
Mechanical life cycle: about 100 million operations
Electrical life cycle: over 1,5 million operations at max. load
Operating ambient temperature: from -40°C to +105°C - (resin sealed model)
Digits CFIB & CFXB not included
ME - Lever limit micro switch
V15
Mechanical contact: SPDT. Switching power: 10A per 30Vdc – 15A per 250Vac (resistance load)
Mechanical life cycle: about 50 million operations
Electrical life cycle: over 1 0 operations at maximum load
Operating ambient temperature: from -25°C to +80°C (Omron)
ABV
Mechanical contact: SPDT gold flashed. Switching power: from 1mA to 500mA per 24Vcc – 3A per 250Vac
Mechanical life cycle: about 5 million operations
Electrical life cycle: over 1 0 operations at maximum load
Operating ambient temperature: from -40°C to +85°C (Panasonic)
Z1S
Mechanical contact: SPDT. Switching power: 6A per 30Vdc – 15A per 250Vac (resistance load)
Mechanical life cycle: about 20 million operations
Electrical life cycle: over 5 0 operations at maximum load
Operating ambient temperature: from -15°C to +80°C.- (dust protection model) (Omron)
DZ
Mechanical contact: DPDT. Switching power: 10A per 30Vdc – 10A per 250Vac (resistance load)
Mechanical life cycle: about 1 million operations
Electrical life cycle: over 5 0 operations at maximum load
Operating ambient temperature: from -25°C to +80°C (Omron)
NOTE: with 3&4 micro switch please contact CEsrl to define digit 1
IN - Inductive sensors
03 Cylindrical - namur NC – incorporable -SIL2 - ATEX Exia - Tamb- 25°C + 100°C – (mod.: NJ2 -12GK-N
05 Rectangular - namur NC – incorporable - SIL2 - ATEX Exia - Tamb -25°+100°c – (mod.: NJ2-V3-N)
RD - Magnetic JETREED
P1
Reed contact: SPDT. 3A-120Vac/dc with switching power from 3 to 100 Watts /VA (resistance load)
Mechanical life cycle: about 100 million operations
Electrical life cycle:over 6 0 operations at maximum load
Operating ambient temperature: from -40°C to +125°C (Hermetically sealed model -IP67)
P2
Reed contact: SPDT. 3A-240Vac/500dc with switching power from 3 to 100 Watts/VA (resistance load)
Mechanical life cycle: about 100 million operations
Electrical life cycle: over 6 0 operations at max. load
Operating ambient temperature: from -25°C to +125°C - (hermetically sealed model -IP67)
P3
Reed contact: SPDT. 1A- 240Vac/dc with switching power 25 Watts/VA (resistance load)
Mechanical life cycle: about 100 million operations
Electrical life cycle: over 6 0 operations at max. load
Operating ambient temperature: from -25°C to +125°C - (hermetically sealed model -IP67)
P4
Reed contact: SPDT . 3A- 240Vac/500dc with switching power from 3 to 100 Watts/VA (resistance load)
Mechanical life cycle: about 100 million operations
Electrical life cycle: over 6 0 operations at max. load
Operating ambient temperature: from -60°C to +125°C - (hermetically sealed model -IP67
OPTION
XX3 To be defined on the selected micro switch, inductive sensor, magnetic GO Switch or JETREED
IP - 4÷20mA Position Transmitter model
T 4-20mA Position transmitter microprocessor based - Calibration angle range: 0°÷ 20° min. 0°÷ 330° max.
H HART 4-20mA Position transmitter microprocessor based - Calibr. angle range: 0°÷ 20° min. 0°÷ 330° max.
DIGIT 5
HOUSING CERTIFICATION
0 Protection IP66/67M
A4 simple apparatus for type of protection Exia (Atex); IP66 - ( used with a protection barrier in order to ensure)
B
Atex certified (CESI 10 ATEX 019X):
EX II1GD Exia IIC T6,T5,T4 EX tD A20 IP66/67 T85°C, T100°C, T135°C (T.amb. da -60°C a +75°/+90°/+100°C) (solo per digit 6 = S)
C
Atex certified (CESI 10 ATEX 019X):
EX II2GD Exia IIC T6,T5,T4 EX tD A21 IP66/67 T85°C, T100°C, T135°C (T.amb. da -60°C a +75°/+90°/+100°C)
E
IECEx certified (IECEx CES 1 16):
Ex db IIC T6/T5/T4, tb IIIC T85/T100/T135°C IP66/67M (Tamb. da -55°C a +60°/+80°/+100°C)
ET
Atex certified (CESI 02 ATEX 078):
EX II 2 GD – Ex d IIC T6/T5/T4 Ex tD A21 IP66 T85/T100/T135°C (Tamb. da -60°C a +60°/+80°/+100°C)
Note: Also available with add GOST R Ex (POCC IT.MJ14.B00230) certified: :- 1ExdIICT6/T5/T4 and DIP A21 Ta 85°/100°/135°C
DIGIT 6
HOUSING MATERIAL
0 Aluminium; (STANDARD)
S AISI 316L Stainless steel
DIGIT 7
POSITION VISUAL DISPLAY
0 Position visual display 3D (0°– 90°) - Color: red (closed) - green (open) - Material: polycarbonate; (STANDARD)
1 Position visual display 3D (0°– 90°) - Color: yellow (closed) - black (open) - Material: polycarbonate
25 Position visual display 3D , Color: yellow with graduates notches and writing Closed. Writing Open applied from 25° to 135°- Material: polycarbonate - (Recommended for linear bottom up valves)
3 Visual b indicator steel made with arrow indicator – red colour
NOTE: See ACCESSORIES for visual indicator with extension. Specific for FIREPROOF covers of actuators/valves